Hysol ® 608 
You may print this page for your file
Epoxy Adhesive 

Description
HYSOL® 608 is a clear, fast setting epoxy adhesive used in many applications where optical clarity and/or fast cure rates are needed. Hysol 608 bonds a variety of materials including metals and plastics.

Features
Clear Easy to Mix              Mix by Weight and Volume
Quick Set                           High Strength                                     Room Temperature or Heat Cure


Typical Properties
                                                       Part A                             PartB                                           Mixed      
Color                                              Milky White                    Amber                                          Clear   
Viscosity, Poise                              2,000-4,500                     200-400                                         -    
Specific Gravity @ 77°F                 1.17                                 1.15                                                -      

Handling
Mixing:  This product requires mixing two components together just prior to application.  Complete mixing is necessary.  The temperature of the separate components prior to mixing is not critical, but they should be close to room temperature.
                                                           Part A                                         Part B
By Weight                                               1                                                  1  
By Volume                                             1                                                  1  
Pot Life @ 77°F,                                20 grams                                    5 minutes       

Application
Mixing - Bulk: Combine Part A (resin) and Part B (hardener) in the correct ratio and mix thoroughly until the color and consistency are uniform.  EPOXI-PATCH® Tube Kits have been designed so that squeezing EQUAL LENGTH BEADS of Part A  5-20 minutes at a maximum of 150°F/66°C temperature.

Mixing - Cartridges: Place cartridge in proper dispenser.  To begin using a new cartridge, remove the cap and dispense a small amount of adhesive, making sure both parts A  5-20 minutes at a maximum of 150°F temperature.


Clean Up: It is important to remove excess adhesive from the work area and application equipment before it hardens. Many common solvents and citrus cleaners are suitable for removing uncured adhesive.   Consult with your supplier's information pertaining to the safe and proper use of solvents.


Performance
Tensile Lap Shear Strength: Tested on etched aluminum per ASTM D 1002.

Cure                                          Test Temp. °F                                Typical Results, psi          

1 Hour @ 77°F                               77                                                      1500
24 Hrs. @ 77°F                              -67                                                      1000
                                                        77                                                       2000
                                                      140                                                         600
                                                      180                                                         200

2 Hrs @ 140°F                              -67                                                        1100
                                                       77                                                         3000
                                                     140                                                           700
                                                     180                                                           250

Bulk Properties
Hardness (Shore D)                                                         80 Minimum @ 77°F
Coefficient of Linear Thermal Expansion                      0/°C@86 to  137°F
Dielectric Strength                                                            1208 volts/mil, 5-18 mil film
Dielectric Constant                                                           3.78 at 77°F,10 Kz
Volume Resistivity                                                           3.87 x 10
14 at 77°F, ohm/cm, 100V
Dissipation Factor                                                            2.1 x 10
-4 at 77°F, 10 Kz
Linear ShrinkageWater Absorption

Packaging

4 gram Foil Packs                                            2.8 oz. Epoxi Patch Tube Kits
50 ml and 200 ml EPS Cartridges                 Quart, One Gallon and Five Gallon Systems

Safety
The Material Safety Data Sheet for Hysol 608 is available upon request.

DISCLAIMER:
The information supplied in this document is for guidance only and should not be construed as a warranty.  All implied warranties are expressly disclaimed.  Including without limitation any warranty of merchantability and fitness for use: All users of the materials are responsible for assuring that it is suitable for their needs, environment and use.  All data is subject to change as Dexter deems appropriate.

Users should review the Material Safety Data Sheet (MSDS) and product label for the material to determine possible health hazards, appropriate engineering controls and precautions to be observed in using the material.  Copies of the MSDS and label are available upon request.

For more information or to order contact the Glu Guru™ at 1-800-323-5158
or
Email mike@on-hand.com