Hysol 609 ® 
You may print this page for your file
Epoxy Adhesive 

 Description
HYSOL® 609 is an exceptional epoxy formulation recommended for lower temperature or wet industrial bonding applications where fast curing is required.  This ultra clear, two part, low viscosity system mixes easily at room temperature.  It is suitable for high performance structural bonding applications requiring a combination of very fast room temperature cure, low shrinkage, excellent mechanical properties.  Fully cured Hysol 609 is an excellent electrical insulator and provides superior resistance to vapors and gases, water, galvanic action, petroleum fuels, salt solution and many other organic and inorganic compounds.

Recommended Substrates: metals, phenolic plastics, polyester, glass and glass fabrics, hardboards and forestry products, ceramics, rubber, masonry materials and other construction materials.

Features
Very Fast Room Temperature              No Solvents                   Easy to Mix
Very Clear                                                Self Leveling

Typical Properties
                                            Part A                                     Part B                                           Mixed     
Color                                   Clear                                       Clear                                              Clear   
Viscosity, Poise                   110-190                                  110-190                                          -   

Handling
Mixing:  This product requires mixing two components together just prior to application.  Complete mixing is necessary.  The temperature of the separate components prior to mixing is not critical, but they should be close to room temperature.

                                                                  Part A                                              Part B
By Weight                                                 100                                                   100  
By Volume                                               1                                                        1  
Pot Life @ 77°F, 20 grams                                              5 minutes       

Application
Mixing - Bulk: Combine Part A (resin) and Part B (hardener) in the correct ratio (1:1) and mix thoroughly until the color and consistency are uniform.  Ratios given above can be used for measuring larger amounts.  Mixing the adhesive just prior to use is recommended.  Heat buildup during or after mixing is normal.  Do not mix quantities greater than 1/2 pound as dangerous heat buildup can occur causing uncontrolled decomposition of the mixed adhesive.  Mixing smaller quantities will minimize the heat buildup.

Mixing - Cartridges: Place cartridge in proper dispenser.  To begin using a new cartridge, remove the cap and dispense a small amount of adhesive, making sure both parts A  B are extruding.  Attach nozzle and dispense approximately 1-2" before applying onto the part to be bonded.  Partially used cartridges should be stored with the mixing nozzle attached.  To reuse, remove and discard the old nozzle, attach the new nozzle, and begin dispensing.

Application:  Bonding surfaces should be clean and dry. For optimum surface preparation, consult Dexter's Bulletin  Preparing the Surface for Adhesive Bonding.  Once the adhesive is applied, the bonded parts should be held in contact until the part has developed handling strength.  It is not necessary to clamp the parts unless movement during cure is likely.

Cure:  Complete cure is obtained after 24 hours at 77°F.  HYSOL 609 will achieve handling strength after 10 minutes at 77°F (note: this can vary with different bond configurations).

Clean Up: It is important to remove excess adhesive from the work area and application equipment before it hardens. Many common solvents and citrus cleaners are suitable for removing uncured adhesive.   Consult with your supplier's information pertaining to the safe and proper use of solvents.

Performance
Tensile Lap Shear Strength: (Tested on etched aluminum per ASTM D1002).

Cure                                                           Test Temp.  °F                                         Typical Results          

24 Hrs. @ 77°F                                          77                                                                1800 psi
    
Bulk Properties
Hardness (Shore D) @ 77°F:                   75 Minimum
Dielectric Strength                                     415 volts/mil
Tensile Strength, psi:                                4200

Packaging
 50 ml and 200 ml EPS Cartridges                                Gallon and Five Gallon Systems

Safety
The Material Safety Data Sheet for HYSOL 609 is available upon request.

DISCLAIMER:
The information supplied in this document is for guidance only and should not be construed as a warranty.  All implied warranties are expressly disclaimed.  Including without limitation any warranty of merchantability and fitness for use: All users of the materials are responsible for assuring that it is suitable for their needs, environment and use.  All data is subject to change as Dexter deems appropriate.

Users should review the Material Safety Data Sheet (MSDS) and product label for the material to determine possible health hazards, appropriate engineering controls and precautions to be observed in using the material.  Copies of the MSDS and label are available upon request.

For more information or to order contact the Glu Guru™ at 1-800-323-5158
or
Email mike@on-hand.com